ERA, ERAF, ERD, ERDF, ERC, ERCF SERIES ELECTRIC FRYERS
VULCAN-HART F-32959 Rev. E (August 2012)
-26-
OIL OUT PROCEDURE:
Use the Boil Out By-Pass™ drain extension allowing the boil
out solution to exit the fry tank without using the filtering
system. Do not allow water to run through the motor / pump.
Drain the boil out solution into a bucket or place a hose on the
end of the drain extension allowing the other end to flow into a
floor drain. In Fig. 6 the arrow is pointing to the drain
extension. It is threaded into the top coupling of the oil drain
tube. Drain extension needs to be only hand tightened.
Boil Out By-Pass™ Extension Tube
Fig. 6
Standard Hose End Drain Tube End
THERMAL OVERLOAD PROTECTION BUTTON:
The motor/pump supplied with the filtering system
has a thermal overload protection circuit that senses
when excess heat occurs due to filtering for long
periods of time or under heavy load prior to
discarding debris buildup. If the thermal overload
protection is tripped, wait 5 minutes and then reset
the motor by pushing in the red button. The arrow in
Figure 7 shows the location of the reset button;
located on the front of the motor / pump facing
towards you.
Fig. 7