LEVELING
Using a spirit level, adjust the leveling feet to level the steamer front-to-back and side-to-side.
Mark hole locations on the floor through the anchoring holes provided in the rear flanged adjustable
feet. Move the steamer and drill holes in the floor at the marked locations. Insert proper anchoring
devices. Set the steamer back in the proper position. Bolt and anchor the leveled steamer securely
to the floor. Seal bolts and flanged feet with Silastic or equivalent compound.
After the drain is connected, check for level by pouring water onto the floor of the compartment.
All water should drain through the opening at the back of the compartment.
SERVICE CONNECTIONS (Fig. 1)
PL-56413
ELECTRICAL CONNECTION
STEAM UNLOADER PORTS
DRAIN
CONDENSING COLD
WATER CONNECTION
GENERATOR WATER
CONNECTION
GAS CONNECTION
UNLESS OTHERWISE SPECIFIED, ELECTRICAL CONNECTION TO BE 120 VOLTS, 60 HERTZ SINGLE PHASE WITH
GROUND. FURNISHED WITH 4 1/2 FOOT CORD WITH 3 PRONG PLUG. MAXIMUM 4.0 AMPS.
DRAIN: 2" IPS PIPED TO OPEN FLOOR DRAIN. NO SOLID CONNECTION. MAXIMUM 24" LENGTH BEFORE
OPEN AIR GAP OPENING. (NO BENDS OR ELBOWS).
GAS CONNECTION: 3/4" IPS SUPPLY LINE REQUIRED.
CONDENSING COLD WATER: 3/8" O.D. TUBING AT 25-50 PSI (170 TO 345 kPa).
GENERATOR WATER: 3/8" O.D. TUBING AT 20 TO 60 PSI (138 TO 413.7 kPa).
SERVICE CONNECTIONS