Fig. 24
DOWN LIMIT SWITCH (3S) - POWER
TILTING OPTION ONLY
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1. Place kettle in the fully upright position.
2. Remove CONTROL BOX COVER (TILTING).
3. Note lead wire locations and disconnect from
down limit switch (3S).
4. Remove adjustment screws (2) securring switch
bracket to mounting plate.
5. Remove mounting nuts and screws (2) securring
down limit switch (3S) to bracket.
6. Reverse procedure to install down limit switch
(3S).
7. Perform DOWN LIMIT SWITCH (3S)
ADJUSTMENT - POWER TILTING OPTION
ONLY.
Fig. 25
DC TILT MOTOR - POWER TILTING
OPTION ONLY
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1. Remove CONTROL BOX COVER (TILTING).
2. Remove motor cover from rear of control box.
Fig. 26
3. Disconnect DC tilt motor lead wires (2) at quick
disconnect terminals. The wires are labeled MTR
positive (+) and MTR negative (-).
4. Disconnect motor ground wire.
5. Remove motor mounting bolts and lock washers
from gear reducer flange.
K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - REMOVAL AND REPLACEMENT OF PARTS