CONTROL PANEL
Fig. 1
TOOLS
Standard
Standard set of hand tools.
Pipe thread sealant (must be resistant to the
action of propane gases).
VOM with an AC current tester (meter sensitivity
should be at least 20,000 ohms per volt).
Temperature meter (thermocouple type) for
checking kettle temperature.
Manometer capable of reading at least 16" W.C.
of gas pressure.
Container that is capable of holding at least 8
gallons of drained reservoir jacket fluid.
Special
Torque wrench capable of tightening combustion
chamber mountings nuts to 30 ft-lbs.
36mm socket to remove sight glass for jacket
fluid draining.
Requires U-inclined (Grainger P/N 3T294) or
digital (Grainger P/N 1XFW2) manometer for
measuring gas pressures and blower air
pressures.
Dowfrost™ heat transfer fluid Part No. 558038 (5
gallon). Refer to FILLING THE RESERVOIR
JACKET for volumes.
Distilled water only for re-filling of the jacket
(purchase locally). Refer to FILLING THE
RESERVOIR JACKET for volumes.
SPECIFICATIONS
Electric
120VAC / 60HZ / 1 phase
5 amp rating.
Supplied with 6 foot power cord and 3-prong
grounding plug (proper ground required).
NOTE: Machines with electronic ignition systems
should be connected to a standard 120VAC electrical
outlet rather than a ground fault circuit interrupter
(GFCI) if possible. Machines connected to certain
GFCI circuits may repeatedly nuisance trip the GFCI.
If the machine must be connected to a GFCI, use Part
No. 913053 (Pass and Seymour) approved by
engineering for use with electronic ignition systems.
Gas Supply
NOTICE The gas supply pressure must not exceed
14” WC (½ PSI). Pressures higher than 14” WC will
damage the equipment’s gas controls and is not
covered under warranty. If the supply pressure
exceeds 14” WC an additional supply line regulator
rated for the supply line pressure (inches WC),
nominal pressure (OUT), and gas flow for the kettle
BTU rating must be installed.
Span gas technology enables "field adjustable
manifold pressure" from natural to propane gas or
propane to natural. All kettles shipped for natural gas
at sea level atmospheric pressure. Requires a U-
Inclined or digital manometer. See TOOLS.
Refer to F35461 Installation & Operation Manual for
specific instructions on GAS CONNECTIONS and
GAS AND ALTITUDE ADJUSTMENTS. A combustion
anaylizer is required for gas type conversions and
altitude adjustments as outlined in these procedures.
K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - GENERAL
Page 5 of 44 F45461 Rev. A (0713)