Installation, Operation and Care of
MODEL G30TB & G40TB GAS TILTING BRAISING PANS
KEEP THESE INSTRUCTIONS FOR FUTURE USE
GENERAL
Vulcan-Hart Gas Tilting Braising Pans are installed on a tubular base and are available in two sizes.
Model G30TB has a 30-gallon capacity and an 80,000 BTU/Hr. input rating. Model G40TB has a 40-
gallon capacity and a 100,000 BTU/Hr. input rating.
The tilting braising pan is a versatile piece of equipment. It allows you to stew, simmer, pan fry, braise,
grill or saute, and all with a very uniform heat pattern.
Standard features include an electronic ignition, tilting switch solid state temperature control,
removable strainer, receiving pan support, and a lid with full width, drop-type handle that can be opened
from any position. Optional accessories include a stainless steel pan support, and steam pan insert.
Vulcan-Hart Company suggests that you thoroughly read this entire manual and carefully follow all of
the instructions provided.
Your Vulcan-Hart Gas Tilting Braising Pan is produced with quality workmanship and material. Proper
installation, usage and maintenance of your tilting braising pan will result in many years of satisfactory
performance.
INSTALLATION
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found
to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Before installing, verify that the type of gas supply (natural or propane) and electrical service agree with
the specifications on the rating plate located on the left side panel as you face the front of the braising
pan. If the supply and equipment requirements do not agree, contact your dealer or Vulcan-Hart
immediately.
LOCATION
The equipment must be kept free and clear of combustible substances. The tilting braising pan, when
installed, must have minimum clearance from combustible and non-combustible construction of 3"
from the sides and 6" from the rear. The tilting braising pan is intended for use on non-combustible
floors.