ROUND TILTING BRAISING PANS - SERVICE PROCEDURES AND ADJUSTMENTS
Pa
e 15 of 24
Potentiometer
Perform the followin
test procedure to verify the
potentiometer is functionin
properly and to confirm
the temperature settin
of the dial. A V-O-M
connected from TC (-) to the wiper (red) on the
potentiometer will read a volta
e that corresponds to
the set point temperature. Ex. If the set point is
300°F the DC volta
e measured at the wiper should
be approximately 1.49 volts.
1. If the thermocouple condition has not
been
verified as described in step 3A above, place a
jumper across TC (-) and TC (+). If the
thermocouple condition has been verified,
proceed to step 2.
NOTE: Remove jumper when test is
completed.
2. Connect the black meter lead of a V-O-M to the
TC (-) on the temperature controller.
3. Connect the red meter lead of a V-O-M to the
red wire (wiper arm) on the potentiometer.
4. Turn the power switch on and set the
temperature dial to 100°F. Increase set point to
200°F, 300°F, 400°F and 450 °F while
monitorin
the volta
e chan
e between dial set
points. Compare the meter readin
s to the
chart below.
TEMPERATURE
SETTING (°F)
APPROXIMATE
DC VOLTAGE
100 0.38
200 0.93
300 1.49
400 2.0
450 2.3
A. If the volta
e measurements a
ree with
those listed in the table and the increase in
volta
e was smooth without drops or
spikes then the potentiometer is
functionin
properly.
B. If the volta
e measurements do not a
ree
with those listed in the table or the
increase in volta
e was not smooth but
with drops or spikes then the
potentiometer is not functionin
properly.
Replace the temperature controller and
potentiometer assembly and check unit for
proper operation.
HEATING ELEMENTS
(ELECTRIC MODEL)
WARNING: THE FOLLOWING STEPS REQUIRE
POWER TO BE APPLIED TO THE UNIT DURING
THE TEST. USE EXTREME CAUTION AT ALL
TIMES.
1. Measure the volta
e at the heatin
element
terminals and verify it a
ainst the data plate
volta
e.
A. If volta
e is incorrect, find the source of
the problem.
2. If volta
e is correct, check current draw (amps)
throu
h the heatin
element lead wires. If
current draw is correct then heatin
element is
ok. See table below for proper values.
A. If current draw is not correct then, replace
heatin
element.
3. Check for proper operation.
VOLTAGE
TOTAL
KW
AMPERAGE
PER LINE
OHMS PER
ELEMENT
1 PH 3 PH
208 7.5 36.1 20.9 17.4
240 7.5 31.3 18.1 23.1
480 7.5 9.0 30.6
NOTE: Values in the table are nominal. Tolerance is
+5/-10 %.
Comments to this Manuals