BURNER AIR SHUTTER
ADJUSTMENT
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas before servicing the
unit.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
The efficiency of the burner depends on a delicate
balance between the air supply and volume of gas.
Whenever this balance is disturbed, poor operating
characteristics and excessive gas consumption may
occur. An air shutter on the front of the burner controls
the gas mixer balance. A yellow streaming flame on
the burner is an indication of insufficient primary air. A
proper flame should be blue in color, well-defined and
seated on the burner port. A white-blue flame is a
result of excessive primary air.
1. Remove
BURNER.
2. Loosen the shutter screw and rotate the air
shutter.
Fig. 21
3. Install burner.
4. Install GAS PRESSURE REGULATOR.
5. Connect power to machine.
6. Turn on power and rotate temperature controller
to call for heat.
7. Observe flame from back of machine.
A. If a proper flame is observed as described
in the beginning paragraph, no further
adjustment is necessary.
B. If flame is yellow tipping and lifting from
burner, continue with procedure to adjust.
8. Disconnect power.
9. Remove burner, being sure to keep shutter in the
current position.
10. Open the shutter slightly and tighten the shutter
screw.
11. Install BURNER.
12. Test machine to verify proper operation.
NOTE: The factory default air shutter positions are
half open natural; full open propane.
REGULATOR ADJUSTMENT
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
NOTE: Regulators come preset, but should be
checked anytime one is installed. Before adjusting
regulator, check incoming gas line pressure. Incoming
pressure must be 7-14" W.C. for natural gas and
12-14" W.C. for propane gas. If incoming pressure is
not correct, have the gas source checked and
adjusted as necessary. Make sure the regulator is
mounted in the horizontal position with the arrow
pointing in the direction of gas flow. See unit data
plate, riveted on right side panel towards front of unit,
for manifold pressure setting information. Clean vent
cap before adjusting.
RRG SERIES HEAVY DUTY GAS GRIDDLE - SERVICE PROCEDURES AND ADJUSTMENTS
Page 13 of 24 F45514 (0214)